INCUBATOR |
To achieve the correct temperature distribution stable It was designated as a forced circulation method, Digital PID Controller Precise temperature control and setting is possible. Air -Warm has a uniform temperature distribution, so wrapped around the outside of the chamber, It is possible to fast temperature recovery after opening.
Operation qualification test Temperature compensation, real-time recorder and record the temperature as software Each position paper by the temperature test Test chamber temperature holding time in case of power failure Return temperature response test when the door is closed after opening 30 seconds
Sliding-Type was equipped with a shelf to shelf to take advantage of the convenient self-test. The precise temperature control is possible by Auto Tuning PID control. There is a temperature safety device to prevent operation was greater than the set temperature more stable. Using a forced circulation system improves the temperature distribution and the drying efficiency. 65 & lt; 0 & gt; C maximum temperature, the distribution & lt; 0 & gt; C 0.1 ± 0.1 & lt; 0 & gt; C to digital PID control close temperature control unit. Overheating protection device. Alarm, timer, was equipped with an auto-tuning, temperature compensation function. Chamber heated air is passed back in the middle, even by a fan motor It was achieved a good temperature distribution through a circular design, a faster drying rate. By heating the diffusion surface to the air of a uniform temperature around the fan's speed (Fan) ensuring high thermal efficiency and temperature uniformity. The heater and the fan motor is not running out of mechanical damage to the foreign object located on the back side of the chamber to the chamber bottom. All corners are rounded goby foreign objects do not leak into the outer chamber is easy to clean and easy maintenance. The shelf with adjustable height with 25mm interval is provided. Dual chamber is surrounded by a layer of air insulation effect of the insulation. If you open the door stops the operation of the heater and fan, and we consider your safety.
SPECIFICATION
MODEL
|
PH-I 100L
|
PH-I 150L
|
||||
Dimension_IN(WxDxH)mm
|
500 x 400 x 500
|
500 x 500 x 600
|
||||
Dimension_OUT(WxDxH)mm
|
635 x 670 x 760
|
635 x 770 x 860 |
||||
Chamber volume(L)
|
100
|
150
|
||||
Heater
|
300w
|
600w
|
||||
Power consumption
|
2.3A
|
2.7A
|
||||
Plug type
|
European 220 VAC STD plug
|
|||||
Electrical requirement
|
220 VAC 50/60 Hz
|
|||||
Electrical
|
Electrical leakage breaker, with the use of fuses which are |
|||||
Sensor
|
PT 100 Ω
|
|||||
Controller
|
Digital PID controller with timer, auto-tuning, 5 kinds of image print out |
|||||
Temp.Heating type
|
Direct heating by stainless steel incolony heater
|
|||||
Temp.Range
|
1 Room ambient + 5 ℃ ~ 70 ℃
|
|||||
Temp.Accuracy
|
±0.1 ℃ at 37℃
|
|||||
Temp.Wait off timer
|
mm:ss 59 / hh:mm 99 / Continuous selectable
|
|||||
Temp.Heat up time to 37℃
|
Within 6 minutes
|
Within 8 minutes
|
||||
Material In
|
Stainless steel SUS-304
|
|||||
Material Out
|
Steel plate with powder coating
|
|||||
Safety device
|
Over heat protector.Heat protective barrier of controller box
|
|||||
Shelves Included
|
2
|
2
|
||||
Option
|
RS-232c or 485 Interface port, software, com port cable, thermal printer |
Branch: 14 Fawzy Soliman St., From El Haram St., Giza, Egypt P.O.Box: 127 Giza, Egypt Code:12515 Tel. Fax:+(202) 33943004 / Mobile: +2 / 01223415321-0111221096-01011811884 |